Download e-book for iPad: Agilent 16517A, 16518A Synchronous State Logic Analyzer by

Read Online or Download Agilent 16517A, 16518A Synchronous State Logic Analyzer (service) PDF

Similar logic books

New PDF release: The Puzzler's Elusion: A Tale of Fraud, Pursuit, and the Art

Genius mathematician, Dr. Dennis Shasha, the following units out his most up-to-date book-length mind-twister. made from many smaller segments, a few of which might be solved by means of ten year-olds and a few that are tougher, the detective paintings calls for not more than highschool geometry and junior highschool algebra.

Download e-book for kindle: Do You Think What You Think You Think? by Julian Baggini, Jeremy Stangroom

Is your mind prepared for an intensive philosophical well-being payment?

The writer of the foreign bestseller The Pig that wishes to Be Eaten and his fellow founding editor of The thinker? s journal have a few thought-provoking questions about your considering: Is what you suspect coherent and constant? or a jumble of contradictions? in case you may well layout a God, what might He, She, or or not it's like? and the way will you fare at the tough terrain of ethics whilst your taboos are less than the highlight?

Here are a dozen philosophical quizzes absolute to make armchair philosophers uncomfortably shift of their seats. The solutions will show what you actually imagine? and it can now not be what you suggestion. enjoyable, not easy, and miraculous, this publication will enable you realize the you you by no means knew you have been.

Logic, Action and Cognition: Essays in Philosophical Logic - download pdf or read online

The current quantity has its beginning in a gathering of philosophers, linguists and cognitive scientists that used to be held at Umea collage, Sweden, September 24-26, 1993. The assembly used to be prepared via the dep. of Philosophy in cooperation with the dep. of Linguistics, and it was once referred to as UmLLI-93, the Umea Colloquium on Dynamic methods in common sense, Language and data.

Download PDF by Pierre-emmanuel Caprace: Abstract homomorphisms of split Kac-Moody groups

This paintings is dedicated to the isomorphism challenge for cut up Kac-Moody teams over arbitrary fields. This challenge seems to be a different case of a extra normal challenge, which is composed in deciding upon homomorphisms of isotropic semi uncomplicated algebraic teams to Kac-Moody teams, whose photo is bounded. seeing that Kac-Moody teams own typical activities on dual structures, and because their bounded subgroups will be characterised via mounted aspect homes for those activities, the latter is basically a stress challenge for algebraic crew activities on dual constructions.

Extra resources for Agilent 16517A, 16518A Synchronous State Logic Analyzer (service)

Example text

Card 3, Pod 1 Threshold Swing ≤ 500 mV _________ _________ Exp. Card 3, Pod 2 Threshold Swing ≤ 500 mV _________ _________ Exp. Card 4, Pod 1 Threshold Swing ≤ 500 mV _________ _________ Exp. Card 4, Pod 2 Threshold Swing ≤ 500 mV _________ _________ Minimum Clock Period Trigger Falling Clock Edge Pass/Fail Pass/Fail _________ _________ Pass/Fail _________ Master Card, Pod 2 Pass/Fail _________ Exp. Card 1, Pod 1 Pass/Fail _________ Exp. Card 1, Pod 2 Pass/Fail _________ Exp. Card 2, Pod 1 Pass/Fail _________ Exp.

If you would like to keep the configurations, then save the configurations to disk prior to loading the PV system. Refer to the User’s Guide for more information on saving configuration files to disk. Access the self-tests For an explanation of the tests, refer to the Self-Tests Descriptions in chapter 8. 1 Disconnect all inputs, then turn on the power switch if the mainframe is not turned on. 2 In the System Configuration menu, touch Configuration. In the pop-up menu, touch Test. If the 16517A/18A module is configured in an Agilent Technologies 16500A mainframe, the PV system disk must be installed in one of the flexible disk drives.

Solder the ground to the ground side of the probe connection. 3–27 Testing Performance To test module setup/hold time Set up the equipment 1 Turn on the equipment required and the Logic Analysis System mainframe. Let them warm up for 30 minutes if you have not already done so. 000 Display Display Mode Averaged # of Averages 8 Screen Dual Bandwidth 20 GHz Set up the logic analyzer 1 Set up the Format menu. a In the Format menu, select State Acquisition Mode Full Channel. b Touch the threshold field under each module pod and select ECL.

Download PDF sample

Rated 4.37 of 5 – based on 22 votes